Specification | DN6 | |
Installation position | optional, preferably horizontal | |
Storage temperature range | (℃) | -20〜80 |
Ambient temperature range (℃) | BY and BDY | -20〜70 |
BYN and BDYN | -20〜50 | |
Weight (Kg) | BY and BDY | 2.4 |
BYN and BDYN | 2.5 | |
Model B ( D ) Yand B ( D ) YN
DN6 |
Measured at (P=1 OObar,Mineral oil HLP4+,40C土5C ) |
|||
Operating pressure(bar) | PortsP,P1-P2 A1 | -A2 ; B1-B2 | Up to 315 |
Port T | Up to 50 | ||
Highest setting pressure ( bar) |
Pressure class 50 | 50 | |
Pressure class 100 | 100 | ||
Pressure class 200 | 200 | ||
Pressure class 315 | 315 | ||
The minimum set pressure at zero point | ( bar) | Please see the performance curve | |
Back pressure of port A | ( bar) | Single zero pressure back to oil tank | |
Flow of pilot oil | (L/min) | 0.6〜1.2 | |
Maximum flow | (L/min) | 30 | |
Pressure fluid | Mineral oil (HL, HLP) to DIN 51 524;For other fluid please consult with us. | ||
Fluid temp. Range | ( ℃) | -20〜80 | |
Viscosity range | ( ℃) | 15+380 | |
Oil cleanliness | (mm2/s ) | Filter is recommended for the highest fluid pollution degree; the lowest specific filtration resistance according to ISO 4406 (C) 20/18/15. | |
Hysteresis | (%) | Plus-minus 1.5 of the highest adjustable pressure | |
Repeatability | (%) | Less than plus-minus 2 of the highest adjustable pressure | |
Linearity | (%) | Plus-minus 3.5 of the highest adjustable pressure | |
Sel value caused by the manufacturing errors - pressure characteristics curve derivation refertothe characteristics curvewhen pressure rising | BY and BDY( % ) | Plus-minus 2.5 of the highest adjustable pressure | |
BYN and BDYN( % ) | Plus-minus 1.5 of the highest adjustable pressure | ||
Phase step corresponding Tu+Tg | 10%-90%( ms ) | Approximately 80 | Depend on the installation |
90%-10%( ms ) | Approximately 50 | ||
Cleanliness | Filter is recommended for the highest fluid pollution degree;the lowest specific filtration resistance according to ISO 4406 (C) 20/18/15. |
Electrical Specification | ||
Voltage type | Direct Voltage 24V | |
Controlling current | (mA ) | (Minimum ) 100, ( Maximum ) 1600 |
Solenoid coil (Ω) |
20℃ Measuring under | 5.4 |
Maximum numerical value | 7.8 | |
Resistance | (%) | 100 |
Electrical connection see | BY and BDY | Plug to connect DIN 175 301 -803 and ISO 4400 Ocket to connect DIN 175 301-803 and ISO 4400 |
BYN and BDYN | Plug to connect DIN EN175 301-803 Ocket to connect DINEN175 301-803 | |
Type of insulation to DIN 40 050 | IP65 has got installed and lockedup plug-in connector |